Bid Banana
PricingBid helpAPILog inStart free trial
Log inStart free trial

Learn more

  • Federal contracts (SAM.gov)The Ultimate Guide to SAM.gov Registration
  • Pricing your quoteWhy Your RFP Pricing Strategy Is Costing You
  • How to answer an RFQRFQ Meaning: What Is an RFQ?
More energy and utilities bids →Must-win bid? Bring in The Bid Lab →
Bid Banana
SearchPricingBid helpBrowse bidsAPISupportFAQPrivacy PolicyTerms of UseAI Use Policy

This website and its content is copyright of The Bid Lab © 2026. The Bid Lab is a trademark of Bid Lab, LLC. All rights reserved.

  1. Bid Banana
  2. ›Closed bids
  3. ›Federal
  4. ›DWA 1500KW Load Bank

U.S. Department Of Defense·Washington

DWA 1500KW Load Bank

Closes 11/12/2025$200k – $500kRequest for Quotation
Bid source

This opportunity has closed.

Bid Banana tracks 1.6M+ bids and awards across all 50 states. Save a search and we'll email your new matches, daily or weekly — so the next one reaches you with time to bid.

Get alerted next time

Description

The US Army Engineer District Walla Walla is seeking a contractor to provide a 1500KW Load Bank for delivery and usage at the Dworshak National Fish Hatchery in Orofino, Idaho. The Load Bank shall meet the minimum salient characteristics specified in the technical specifications. The contractor shall provide all documentation required in the solicitation and deliver the Load Bank within 25 weeks of contract award. The contractor shall also provide a minimum one-year warranty on all parts, labor, and workmanship from factory defects. • The Load Bank shall have a capacity of 1500KW, be of resistive type for outdoor use, and have a power factor of 1.0. • The Load Bank shall have a voltage of 3-phase 480V and a frequency of 60 Hz. • The Load Bank shall have load steps of 25KW resolution and a duty cycle of continuous. • The Load Bank shall have PLC control with monitoring and data acquisition and remote control capability with Modbus RS-485 communication. • The Load Bank shall have system protection, including fan failure, high exhaust temperature, high intake temperature, malfunction protection, lockout, and alarm. • The Load Bank shall have overload, short circuit, and malfunction protection. • The Load Bank shall have anti-condensation heaters with thermostatic control and a maximum ambient temperature of 120F. • The Load Bank shall have forced air cooling, vertical airflow, and top exhaust. • The Load Bank shall have a fan motor of 3-phase, 230/460V, 30 HP, TEFC. • The Load Bank shall have an airflow of 60,000 CFM. • The Load Bank shall have a three-part, powder-coated, double-walled enclosure. • The Load Bank shall have resistive load elements constructed of stainless steel, Alloy FeCrAl, and ceramic clad, and rated for a minimum of 1080F maximum operating temperatures and 1920F maximum continuous temperature. • The Load Bank shall be UL Listed and UL recognized.

Attached files

Contact

Tonya French(Contracting Officer)

[email protected]

(509) 527-7232

Key dates

Opened
10/28/2025
Closes
11/12/2025
Duration
25 weeks

Last updated

Details

Type
Request for Quotation
Industry
Energy and Utilities
NAICS
335312
Solicitation №
W912EF26QA007

Budget estimate

$200,000 – $500,000

Based on the technical specifications of the Load Bank and the delivery requirements, the estimated budget for this contract could be in the range of $200,000 to $500,000. This estimate is influenced by the complexity of the Load Bank, the materials required, and the labor costs associated with its manufacture and delivery.

AI estimate from the solicitation

Similar opportunities

Matched by Bid Banana AI™

Bid Banana · 1.6M+ bids and awards 🍌

You found this one too late. Don't find the next one too late.

Bid Banana searches open government bids across all 50 states, updated daily. Save a search once and we email you your new matches, daily or weekly, while there is still time to win them.

1.6M+
bids & awards
All 50
states
4,000+
agencies
Start your 7-day free trial

Plans from $49.99/month. Cancel anytime, no setup fees.

Built by The Bid Lab, answering RFPs since 2017.

U.S. Department Of Defense·Pennsylvania

Top match · 57%

61--MODULE HIGH VOLTAGE

Closes 11/2/2026Opened 9/18/2026

U.S. Department Of Defense·United States of America

57% match

61--POWER SUPPLY

Closes 11/12/2026Opened 10/29/2026

U.S. Department Of Defense·Maryland

57% match

Diesel Engine, Starter Motor, Magnetic Contactors, Powerpack & Alternators Supporting 800kW, 60 Hz DPGDS - Non-Commercial NSN's

Closes 11/9/2026Opened 10/8/2026

U.S. Department Of Defense·United States of America

57% match

39--BINDER,LOAD

Closes 11/8/2026Opened 10/28/2026

U.S. Department Of Defense·Maryland

57% match

Diesel Engine, Starter Motor, Magnetic Contactors, Powerpack & Alternators Supporting 800kW, 60 Hz DPGDS - Commercial NSN's

Closes 11/9/2026Opened 10/15/2026

U.S. Department Of Defense·United States of America

56% match

61--POWER SUPPLY

Closes 11/11/2026Opened 10/27/2026

U.S. Department Of Defense·United States of America

56% match

61--POWER SUPPLY

Closes 11/1/2026Opened 10/18/2026

U.S. Department Of Defense·Oklahoma

56% match

61--MOTOR,DIRECT CURRENT

Closes 11/4/2026Opened 10/25/2026

U.S. Department Of Defense·United States of America

56% match

PWA DIFF MODE INDCT

Closes 11/2/2026Opened 10/19/2026

U.S. Department Of Defense·United States of America

56% match

39--BINDER,LOAD

Closes 11/8/2026Opened 10/28/2026

South Carolina Rural Water Association (SCEMD Grant)·South Carolina

56% match

Mobile Diesel Generator - 100kW

Closes 11/23/2026Opened 10/19/2026

California Energy Commission·California

56% match

GFO-26-503 - Distributed Electricity Backup Assets Program - Distributed Energy Resources (DERs) for Grid Reliability

Closes 1/26/2027Opened 10/23/2026

U.S. Department Of Defense·United States of America

56% match

61--POWER SUPPLY

Closes 11/1/2026Opened 10/18/2026

U.S. Department Of Defense·United States of America

56% match

POWER SUPPLY

Closes 11/9/2026Opened 10/9/2026

U.S. Department Of Defense·United States of America

56% match

EURO-DIESEL DRUPS (DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY)

Closes 11/29/2026Opened 10/30/2026

U.S. Department Of Defense·Michigan

56% match

Pump Unit, Hydraulic

Closes 11/3/2026Opened 10/15/2026

U.S. Department Of Defense·United States of America

55% match

39--BINDER,LOAD

Closes 11/8/2026Opened 10/28/2026

U.S. Department Of Defense·Oklahoma

55% match

35K lb. Base Capacity 4-wheel Sit-Down AC Electric Lift Truck, including Options, Battery, Charger, and Freight

Closes 11/9/2026Opened 10/30/2026

U.S. Department Of Defense·Alabama

55% match

Power Supply

Closes 11/2/2026Opened 10/27/2026

U.S. Department Of Defense·United States of America

55% match

Replace DSN-HDD Generator for 78th Signal Battalion, Camp Zama, Japan.

Closes 11/9/2026Opened 10/18/2026

U.S. Department Of Defense·United States of America

55% match

59--SWITCH,PRESSURE

Closes 11/1/2026Opened 10/22/2026

Massachusetts Peabody Municipal Light Plant·Massachusetts

55% match

THREE PHASE 23KV PADMOUNT TRANSFORMERS

Closes 11/5/2026Opened 10/20/2026

U.S. Department Of Defense·United States of America

55% match

61--POWER SUPPLY

Closes 11/3/2026Opened 10/20/2026

U.S. Department Of Defense·California

55% match

29--IGNITION UNIT,LOW VOLT

Closes 11/8/2026Opened 10/27/2026

U.S. Department Of Defense·United States of America

55% match

59--SWITCH,SENSITIVE

Closes 11/4/2026Opened 10/25/2026