The U.S. Navy is soliciting contractors to repair, test, and inspect a specific power‑supply assembly (NSN 4031003‑920, P/N 6130‑013343042) in accordance with detailed technical publications and Navy standards. The contractor must provide all labor, facilities, parts, tooling, and quality‑assurance processes required to return the unit to a Ready‑For‑Issue (RFI) condition within a 90‑day Repair Turn‑Around Time (RTAT). Government‑furnished equipment is limited; the contractor is responsible for any special tooling, test equipment, and compliance with wiring material specifications (SAE‑AS22759 instead of MIL‑W‑81381). The work will be performed at the contractor’s facility located at 6200 J S McDonnell Blvd, St. Louis, MO. The contract includes strict configuration‑management, quality‑system (ISO 9001/AS9100), and calibration requirements, as well as procedures for handling Beyond Economic Repair (BER), Missing on Induction (MOI), and Over‑and‑Above Repair (OAR) items.
• Repair, overhaul, testing, and inspection of the listed power‑supply unit.
• Must meet a 90‑day RTAT per asset and maintain detailed CAV reporting.
• Contractor supplies all parts, tools, and quality‑system documentation; no government‑furnished tooling.
• Compliance with wiring material, MIL‑STD‑454, IPC/EIAJ‑STD‑001C, and other Navy specifications required.
• Location of work: St. Louis, Missouri (Boeing facility).
• Required ISO 9001/AS9100 quality program and ANSI/NCSL‑Z540.3 calibration system.
• Reporting and approval procedures for BER, MOI, OAR, and configuration changes.