The City of Albany is seeking bids for the rehabilitation and upgrade of Well No. 35. The project includes the installation of a new water-lubricated vertical turbine well pump, discharge head assembly, column pipe, and other related accessories. The contractor will be responsible for conducting a flow test, vibration test, and Rossum Sand Test to ensure the pump meets the specified design flow rate and vibration standards. The project also involves the installation of a pre-lubrication system, air line water level measurement device, and other electrical and mechanical components.
• The project requires the contractor to match the existing pump's performance and design criteria.
• The contractor must conduct a flow test for a minimum of eight continuous hours to ensure the pump meets the specified design flow rate.
• The contractor must perform a vibration test to ensure the coupled pump and motor vibration does not exceed the specified standards.
• The contractor must provide a pre-lubrication system, air line water level measurement device, and other electrical and mechanical components.
• The project involves the installation of a new discharge head assembly, column pipe, and other related accessories.