Bid Banana
PricingBid helpAPILog inStart free trial
Log inStart free trial

Learn more

  • Federal contracts (SAM.gov)The Ultimate Guide to SAM.gov Registration
  • Pricing your quoteWhy Your RFP Pricing Strategy Is Costing You
  • How to answer an RFQRFQ Meaning: What Is an RFQ?
More manufacturing bids →Must-win bid? Bring in The Bid Lab →
Bid Banana
SearchPricingBid helpBrowse bidsAPISupportFAQPrivacy PolicyTerms of UseAI Use Policy

This website and its content is copyright of The Bid Lab © 2026. The Bid Lab is a trademark of Bid Lab, LLC. All rights reserved.

  1. Bid Banana
  2. ›Closed bids
  3. ›Federal
  4. ›LIQUID PUMP

U.S. Department Of Defense·Hawaii

LIQUID PUMP

Closes 7/23/2026$10k – $50kRequest for Quotation
Bid source

This opportunity has closed.

Bid Banana tracks 1.6M+ bids and awards across all 50 states. Save a search and we'll email your new matches, daily or weekly — so the next one reaches you with time to bid.

Get alerted next time

Description

The Naval Shipyard in Pearl Harbor requires a liquid pump with specific technical requirements, including a power rating of 6 HP and a nominal pressure ratio of 35:1. The pump must be manufactured by Haskel, with a part number of GSF35-51331. The contractor must provide a firm fixed price for the pump and shipping. The government reserves the right to make a single award to the offeror whose offer is considered in the best interest of the government, price and other factors considered. * Key features of the pump: * Power rating: 6 HP * Nominal pressure ratio: 35:1 * Maximum outlet pressure: 4,375 PSIG * Maximum air drive pressure: 125 PSIG * Displacement per cycle: 6.00 cubic inches * The contractor must provide documentation to demonstrate the item's conformance to the technical requirements. * The government may request evidence of the technical acceptability of the product offered.

Attached files

Contact

Amanda Ragsdale(Contracting Officer)

[email protected]

(808) 285-0182

Key dates

Opened
7/22/2026
Closes
7/23/2026

Last updated

Details

Type
Request for Quotation
Industry
Manufacturing
NAICS
333914
Solicitation №
SPMYM4-26-Q-3518

Budget estimate

$10,000 – $50,000

The budget for this opportunity is estimated to be around $10,000 to $50,000, based on the technical requirements of the liquid pump and the firm fixed price nature of the contract. The exact budget will depend on the offeror's pricing and the government's evaluation of the offers. Factors that may influence the budget include the cost of materials, labor, and shipping, as well as the offeror's profit margin.

AI estimate from the solicitation

Similar opportunities

Matched by Bid Banana AI™

Bid Banana · 1.6M+ bids and awards 🍌

You found this one too late. Don't find the next one too late.

Bid Banana searches open government bids across all 50 states, updated daily. Save a search once and we email you your new matches, daily or weekly, while there is still time to win them.

1.6M+
bids & awards
All 50
states
4,000+
agencies
Start your 7-day free trial

Plans from $49.99/month. Cancel anytime, no setup fees.

Built by The Bid Lab, answering RFPs since 2017.

U.S. Department Of Defense·United States of America

Top match · 67%

43--HOUSING,LIQUID PUMP

Closes 11/17/2026Opened 10/7/2026

U.S. Department Of Defense·Maine

66% match

43--HOUSING,LIQUID PUMP

Closes 11/17/2026Opened 10/7/2026

U.S. Department Of Defense·Virginia

65% match

Liquid Surge

Closes 12/14/2026Opened 10/14/2026

Texas Tx Dept Crim. Justice/inst Div·Texas

63% match

Water Pumps

Closes 11/6/2026Opened 10/23/2026

U.S. Department Of Defense·Ohio

63% match

Vacuum Turbo Pumps

Closes 11/13/2026Opened 10/14/2026

St. John the Baptist Parish Government·Louisiana

63% match

Bid 2026.26 Submersible Pumps

Closes 11/20/2026Opened 10/28/2026

U.S. Department Of Defense·United States of America

63% match

43--HOUSING,LIQUID PUMP

Closes 11/8/2026Opened 10/29/2026

U.S. Department Of Defense·District of Columbia

63% match

Turbomolecular Pumping Station

Closes 10/31/2026Opened 10/27/2026

LA General Services·California

62% match

VOLUTE SUBMERSIBLE PUMP

Closes 11/3/2026Opened 10/28/2026

U.S. Department Of Defense·United States of America

62% match

PUMP,RECIPROCATING

Closes 11/2/2026Opened 10/27/2026

U.S. Department Of Defense·United States of America

62% match

PUMP,ROTARY

Closes 11/16/2026Opened 10/19/2026

U.S. Department Of Defense·Michigan

62% match

Pump Unit, Hydraulic

Closes 11/3/2026Opened 10/15/2026

U.S. Department Of Defense·Texas

61% match

PUMP, CENTRIFUGAL, COOLANT

Closes 11/4/2026Opened 10/21/2026

U.S. Department Of Defense·United States of America

61% match

TRANSMITTER,LIQUID

Closes 11/5/2026Opened 10/8/2026

U.S. Department Of Energy·Tennessee

61% match

Dry Vacuum Pump

Closes 11/6/2026Opened 10/30/2026

U.S. Department Of Defense·United States of America

61% match

PUMP UNIT, FUEL TRAN

Closes 11/23/2026Opened 10/21/2026

City of Charlotte·North Carolina

61% match

Service Water Improvements and Flow Meter Modifications

Rolling / TBD closeOpened 1/31/2026

NYS Rockland County·New York

60% match

Submersible Pump-ESSCO Vortex pump or approved equal

Closes 11/10/2026Opened 10/15/2026

Sewerage and Water Board of New Orleans·Louisiana

60% match

Submersible Sewage Pumps

Closes 11/12/2026Opened 10/21/2026

U.S. Department Of Defense·United States of America

60% match

29--PUMP,FUEL,METERING AND

Closes 11/4/2026Opened 10/21/2026

U.S. Department Of Defense·United States of America

60% match

PUMP,FUEL,METERING

Closes 11/20/2026Opened 10/21/2026

U.S. Department Of Defense·United States of America

60% match

43--PUMP,HYDRAULIC

Closes 11/1/2026Opened 10/22/2026

St. Bernard Parish Government·Louisiana

60% match

Grundfos SLV Pumps or Equal St. Bernard Parish Government Department of Public Works Water and Sewer Division

Closes 11/17/2026Opened 10/29/2026

LA General Services·California

60% match

MOTOR, #4958-0028 PERISTALIC PUMP, MFR. UNIVERSAL ANALYZERS

Closes 11/4/2026Opened 10/30/2026

U.S. Department Of Energy·Tennessee

60% match

Standard Multi-Roots Compact Dry Roughing Pump

Closes 11/4/2026Opened 10/28/2026