Bid Banana
PricingBid helpAPILog inStart free trial
Log inStart free trial

Learn more

  • Washington guideWashington Bids and Bidding Guide
  • Pricing your quoteWhy Your RFP Pricing Strategy Is Costing You
  • How to answer an RFQRFQ Meaning: What Is an RFQ?
More energy and utilities bids →Must-win bid? Bring in The Bid Lab →
Bid Banana
SearchPricingBid helpBrowse bidsAPISupportFAQPrivacy PolicyTerms of UseAI Use Policy

This website and its content is copyright of The Bid Lab © 2026. The Bid Lab is a trademark of Bid Lab, LLC. All rights reserved.

  1. Bid Banana
  2. ›Closed bids
  3. ›Washington
  4. ›Energy and Utilities
  5. ›115 kV Power Circuit Breaker Maltby Switching Station

Snohomish County PUD·Washington

115 kV Power Circuit Breaker Maltby Switching Station

Closes 11/5/2025$500k – $2MRequest for QuotationLogin required
Bid source

This opportunity has closed.

Bid Banana tracks 1.6M+ bids and awards across all 50 states. Save a search and we'll email your new matches, daily or weekly — so the next one reaches you with time to bid.

Get alerted next time

Description

The Snohomish County PUD is seeking a vendor to provide a 115 kV power circuit breaker for the Maltby Switching Station. The circuit breaker must be an outdoor, SF6 puffer type, rated for operation on a nominal 115kV effectively grounded power system. The circuit breaker shall be designed for three-pole gang tripping and closing, and shall meet the requirements of the latest revision of IEEE Std C37.04. • The circuit breaker shall have a rated nominal voltage of 115kV RMS and a rated maximum voltage of 126.5kV RMS. • The circuit breaker shall have a rated continuous current of 2000 amperes RMS and an interrupting current rating of 40,000 amperes symmetrical at rated maximum voltage. • The circuit breaker shall have a rated basic impulse level of 550kV and a rated interrupting time of 3 cycles maximum. • The circuit breaker shall be equipped with devices that prevent tripping and closing when any operational pressure falls to a value below which the circuit breaker cannot safely interrupt at its full interrupting rating. • The circuit breaker shall be designed and constructed to ensure against any gas leakage, and shall have a minimum continuous thermal current rating factor of 2.0. The vendor shall provide all necessary documentation, including drawings and test reports, and shall ensure that the circuit breaker is designed, manufactured, assembled, and tested in accordance with the requirements of this specification.

Attached files

Contact

Cindy Shelton(Bid Contact)

[email protected]

(425) 783-5545

Key dates

Opened
10/15/2025
Closes
11/5/2025

Last updated

Details

Type
Request for Quotation
Industry
Energy and Utilities
NAICS
335311
Solicitation №
25-1608-CS

Budget estimate

$500,000 – $2,000,000

Based on the complexity and specificity of the requirements, the estimated budget for this project could be in the range of $500,000 to $2,000,000. This estimate is based on the assumption that the vendor will need to provide a high-quality circuit breaker that meets all the requirements specified in the document, including the design, manufacturing, testing, and documentation. The actual budget could be higher or lower, depending on the vendor's experience, the materials and labor required, and other factors.

AI estimate from the solicitation

Similar opportunities

Matched by Bid Banana AI™

Bid Banana · 1.6M+ bids and awards 🍌

You found this one too late. Don't find the next one too late.

Bid Banana searches open government bids across all 50 states, updated daily. Save a search once and we email you your new matches, daily or weekly, while there is still time to win them.

1.6M+
bids & awards
All 50
states
4,000+
agencies
Start your 7-day free trial

Plans from $49.99/month. Cancel anytime, no setup fees.

Built by The Bid Lab, answering RFPs since 2017.

Chelan County PUD·Washington

Top match · 69%

115 kV Circuit Breakers

Closes 11/5/2026Opened 9/29/2026

Hastings Utilities·Nebraska

66% match

DHPC PDC 13.8KV Switchgear (Re-bid) HU 2026-49

Rolling / TBD closeOpened 9/4/2026

U.S. Department Of Defense·United States of America

66% match

CIRCUIT BREAKER

Closes 11/2/2026Opened 10/1/2026

Massachusetts Bay Transportation Authority·Massachusetts

66% match

IFB137-26 25KV AC Overhead Contact System - Motorized Operated Disconnect Switches

Closes 11/3/2026Opened 10/7/2026

U.S. Department Of Defense·United States of America

65% match

59--CIRCUIT BREAKER, IN REPAIR/MODIFICATION OF

Closes 11/20/2026Opened 10/6/2026

U.S. Department Of Defense·United States of America

65% match

CIRCUIT BREAKER

Closes 11/20/2026Opened 10/21/2026

The City of Columbus·Ohio

64% match

RFQ033961 - 6009 HCWP ABB BREAKER BID

Closes 11/3/2026Opened 10/28/2026

U.S. Department Of Homeland Security·Maryland

64% match

CIRCUIT BREAKERS

Closes 11/12/2026Opened 10/28/2026

U.S. Department Of Defense·United States of America

64% match

59--CIRCUIT BREAKER

Closes 11/4/2026Opened 10/21/2026

U.S. Department Of Defense·United States of America

63% match

59--CIRCUIT BREAKER, IN REPAIR/MODIFICATION OF

Closes 11/20/2026Opened 10/6/2026

U.S. Department Of Defense·Pennsylvania

63% match

CIRCUIT BREAKER

Closes 11/2/2026Opened 10/1/2026

U.S. Department Of Defense·United States of America

63% match

59--CIRCUIT BREAKER

Closes 11/9/2026Opened 10/26/2026

U.S. Department Of Defense·United States of America

63% match

59--CIRCUIT BREAKER

Closes 11/4/2026Opened 10/21/2026

U.S. Department Of Homeland Security·California

63% match

400 Amp Enclosed Circuit Breaker Disconnects

Closes 11/10/2026Opened 10/29/2026

City of Pasadena·California

62% match

Disconnect Switches 35kV

Closes 11/27/2026Opened 10/28/2026

U.S. Department Of Defense·Kansas

62% match

Switchgear Transformer Replacement

Closes 11/16/2026Opened 10/28/2026

Collin County Community College District·Texas

62% match

McKinney Main Building Switchboard Replacement

Closes 11/6/2026Opened 10/16/2026

U.S. Department Of Defense·United States of America

62% match

59--CIRCUIT BREAKER

Closes 11/1/2026Opened 10/22/2026

Massachusetts Town of Wellesley·Massachusetts

62% match

RFP No. 27E-10-27

Closes 12/10/2026Opened 10/27/2026

Power Authority of New York·New York

62% match

DISCONNECT SWITCHES

Closes 11/18/2026Opened 10/27/2026

U.S. Department Of Defense·Oklahoma

62% match

15kV Switchgear & Station Service Replacement at Lake Tenkiller, OK

Closes 11/10/2026Opened 10/27/2026

U.S. Department Of Defense·United States of America

61% match

59--CIRCUIT BREAKER

Closes 11/4/2026Opened 10/21/2026

U.S. Department Of Defense·Ohio

61% match

Repair Electrical Systems

Closes 11/12/2026Opened 10/1/2026

Alabama State Port Authority·Alabama

61% match

BID – McDuffie 43E Low Voltage Switchboard

Closes 11/12/2026Opened 10/1/2026

U.S. Department Of Homeland Security·Connecticut

61% match

Inspect and Repair of 13.2KV Main Switchgear

Closes 11/12/2026Opened 10/30/2026