The City of Cincinnati, on behalf of the Metropolitan Sewer District of Greater Cincinnati, is seeking a vendor to supply, deliver, start‑up, and train on a complete oil‑free air‑compressor system for the Mill Creek Waste‑Water Treatment Plant. The contract is fixed‑price, firm‑and‑fixed, and requires the equipment to meet extensive performance, safety, and European/US standards, along with a 24‑month warranty and on‑site training. Bidders must be registered in the City’s Vendor Self‑Service portal, provide mandatory insurance, and attend a required site‑visit prior to bid submission.
• Provide one oil‑free air compressor with integrated dryer, vertical 200‑gallon (or larger) receiver, VFD, and Allen‑Bradley PLC with Ethernet and full data logging.
• Meet performance specs: 8 SCFM nominal flow, 62.9 ± 1 ACFM @ 141 psi, 480 V 3‑phase power, ≤ 65 dB(A) noise, and all applicable ASME, EN, IEC, and ISO standards.
• Deliver to 1600 Gest St, Cincinnati, OH 45204, provide startup support, one‑hour on‑site training, complete documentation, and a 24‑month warranty; MSDGC handles physical installation.