Bid Banana
PricingBid helpAPILog inStart free trial
Log inStart free trial

Learn more

  • Colorado guideColorado Bids and Bidding Guide
  • Construction RFPsConstruction Bids and Bidding Guide
  • How to answer an IFBInvitation for Bid: You Just Received an IFB, Now What?
More construction bids →Must-win bid? Bring in The Bid Lab →
Bid Banana
SearchPricingBid helpBrowse bidsAPISupportFAQPrivacy PolicyTerms of UseAI Use Policy

This website and its content is copyright of The Bid Lab © 2026. The Bid Lab is a trademark of Bid Lab, LLC. All rights reserved.

  1. Bid Banana
  2. ›Closed bids
  3. ›Colorado
  4. ›Construction
  5. ›2024-063M23 Replace Fire Detection Fire Suppression Systems

Colorado Department of Human Services·Colorado

2024-063M23 Replace Fire Detection Fire Suppression Systems

Closes 3/31/2026$500k – $2MInvitation for Bid
Bid source

This opportunity has closed.

Bid Banana tracks 1.6M+ bids and awards across all 50 states. Save a search and we'll email your new matches, daily or weekly — so the next one reaches you with time to bid.

Get alerted next time

Description

The project involves replacing fire detection and fire suppression systems at various buildings. The contractor will need to verify existing conditions, remove devices and equipment no longer required, and provide new components and accessories as needed. The fire alarm system must be loop-connected via fiber optic cable, and communication between fire alarm control panels must be maintained even if a single fiber optic cable is damaged. The contractor must also coordinate with the local jurisdiction and fire alarm supplier. Some key points to consider: • The contractor must provide a building-wide duct cleaning before installation. • All fire alarm detection devices must be covered during the cleaning service, and the fire alarm system must be taken off-line. • The system must remain off-line for at least 3 hours after cleaning before being put back into service. • The contractor must provide an anti-ligature, correctional grade protective cover for devices indicated with a "WG". • The air sampling system tubing must be routed concealed and in secure locations. • The contractor must provide an access door at sample port locations. • Smoke detectors must be located per NFPA 72 and manufacturer's requirements, and not within 3 feet of any ceiling-mounted air supply device.

Attached files

Contact

Jamie Gott(BUYR_NM (likely Buyer or Procurement Manager))

[email protected]

Key dates

Opened
3/20/2026
Closes
3/31/2026

Last updated

Details

Type
Invitation for Bid
Industry
Construction
NAICS
238210
Solicitation №
IFB1-IHHA-2026000143-3

Budget estimate

$500,000 – $2,000,000

Estimating the budget for this project is challenging without specific details on the scope and materials required. However, considering it involves replacing fire detection and suppression systems across multiple buildings, the cost could be substantial. Factors influencing the likely payment range include the number of buildings, the complexity of the systems, the materials needed, and the labor costs. A rough estimate for such a project could range from $500,000 to $2,000,000, depending on the specifics of the work involved.

AI estimate from the solicitation

Similar opportunities

Matched by Bid Banana AI™

Bid Banana · 1.6M+ bids and awards 🍌

You found this one too late. Don't find the next one too late.

Bid Banana searches open government bids across all 50 states, updated daily. Save a search once and we email you your new matches, daily or weekly, while there is still time to win them.

1.6M+
bids & awards
All 50
states
4,000+
agencies
Start your 7-day free trial

Plans from $49.99/month. Cancel anytime, no setup fees.

Built by The Bid Lab, answering RFPs since 2017.

Nevada State Public Works Division·Nevada

Top match · 73%

Fire Suppression System, Army Aviation Support Facility (25-S03g-3)

Closes 11/4/2026Opened 8/21/2026

University of Missouri-Columbia·Missouri

72% match

Telecom Building - Fire Alarm System Upgrades (CP252751)

Closes 11/5/2026Opened 9/9/2026

LA Ontario International Airport Authority·California

70% match

2027PS001 - Campus-Wide Fire Alarm System Replacement

Closes 11/9/2026Opened 9/25/2026

U.S. Department Of Defense·Alaska

70% match

(EAR048) Repair Fire Alarm System Eareckson Air Station Facilities

Closes 11/16/2026Opened 10/26/2026

Bedford County·Virginia

70% match

(2027-3) IFB: HYBRID FIRE EXTINGUISHING SYSTEM INSTALLATION

Closes 11/9/2026Opened 10/2/2026

New York City Department of Environmental Protection·New York

69% match

82626B0051-MFP-2025 Preventative Maintenance, Inspection, Testing and Repair of Fire Protection Systems and Fire Alarm Systems at Various DEP Facilities

Closes 11/10/2026Opened 10/14/2026

U.S. Department Of Veterans Affairs·New York

69% match

C1DA--NRM A/E- 528A7-27-112 Fire Alarm Panel Upgrade

Closes 11/3/2026Opened 10/20/2026

California Military Department·California

69% match

IFB 133896 Fire Alarm System Replacement

Closes 12/1/2026Opened 10/27/2026

U.S. Department Of Defense·Florida

69% match

FIRE APPARATUS INTERCOM SYSTEM UPLIFT AND INSTALLATION

Closes 9/4/2027Opened 8/24/2026

U.S. Department Of Justice·Hawaii

69% match

Upgrade Fire Detection System at FDC Honolulu, Hawaii

Closes 11/4/2026Opened 10/15/2026

University of Massachusetts·Massachusetts

69% match

UMA27-09 ISB, Linden, LSL, PSB, AFFF Fire Protection System Replacements

Closes 11/30/2026Opened 10/21/2026

Iowa Department of Administrative Services·Iowa

69% match

Fire Panel System

Closes 11/3/2026Opened 10/2/2026

El Paso ISD·Texas

69% match

Districtwide Fire Suppression Replacement, Maintenance, and Repair

Closes 11/12/2026Opened 10/20/2026

U.S. Department Of The Interior·Wisconsin

68% match

Z--SACN Replace Fire Alarms and Intrusions Systems

Closes 11/30/2026Opened 10/19/2026

The City of Columbus·Ohio

68% match

RFQ033947 - 2601 FM200 Fire Suppression System Maintenance

Closes 11/4/2026Opened 10/27/2026

Ontario International Airport·California

68% match

2027PS001 - Campus-Wide Fire Alarm System Replacement

Closes 11/23/2026Opened 9/25/2026

U.S. Department Of Defense·United States of America

68% match

29--FIRE DETECTOR ASSY

Closes 11/8/2026Opened 10/25/2026

University of Massachusetts Amherst·Massachusetts

68% match

UMA27-09 ISB, Linden, LSL, PSB, Aqueous Film-Forming Foam (AFFF) Fire Protection System Replacement

Closes 11/30/2026Opened 10/21/2026

U.S. Department Of Veterans Affairs·Wisconsin

68% match

Z1DA--Upgrade Fire Alarm System Construction 676-22-110

Closes 12/1/2026Opened 10/7/2026

California Highway Patrol·California

68% match

IFB 26C450003 - CHP Madera Fire & security Alarm Monitoring Services

Closes 11/3/2026Opened 10/20/2026

Massachusetts Department of Public Health·Massachusetts

68% match

DPH-2027-001 FIRE ALARM AND SUPPRESSION

Closes 11/30/2026Opened 10/22/2026

University of Massachusetts System·Massachusetts

68% match

UMA27-09 ISB, Linden, LSL, PSB, AFFF Fire Protection System Replacement | #AMHADM-2027-1156

Closes 11/30/2026Opened 10/21/2026

Iowa Department of Administrative Services·Iowa

68% match

Fire Panel Systems

Closes 11/3/2026Opened 10/2/2026

Aldine ISD·Texas

68% match

Fire Suppression and Fire Alarm Upgrades

Closes 11/19/2026Opened 10/26/2026

Christopher Newport University·Virginia

67% match

CNU Library Fire Alarm Replacement, 242-B4242-016

Closes 11/10/2026Opened 10/1/2026