Bid Banana
PricingBid helpAPILog inStart free trial
Log inStart free trial

Learn more

  • New York guideNew York Bids and Bidding Guide
  • Before you submitBid Response: 3 Common Mistakes When Submitting an RFP
More engineering services bids →Must-win bid? Bring in The Bid Lab →
Bid Banana
SearchPricingBid helpBrowse bidsAPISupportFAQPrivacy PolicyTerms of UseAI Use Policy

This website and its content is copyright of The Bid Lab © 2026. The Bid Lab is a trademark of Bid Lab, LLC. All rights reserved.

  1. Bid Banana
  2. ›Closed bids
  3. ›New York
  4. ›Engineering Services
  5. ›Elmira Correctional Facility Electrical Switchgear…

NYS LND Technical Services, LLC·New York

Elmira Correctional Facility Electrical Switchgear Testing/Partial Discharge Testing

Closes 10/2/2026$150k – $300kRequest for QualificationLogin required
Bid source

This opportunity has closed.

Bid Banana tracks 1.6M+ bids and awards across all 50 states. Save a search and we'll email your new matches, daily or weekly — so the next one reaches you with time to bid.

Get alerted next time

Description

LND is seeking New York State (NYS) - certified SDVOB Firms to partner with us as subcontractors on this solicitation. ----------------------------------------------------------------------------------- FACILITY OVERVIEW: Bldg. 108 Generator building The facility is powered via two (2) incoming 12.47kv utility electrical services. The incoming service consists of one (1) Square D Type VR circuit Breaker protected by one (1) GE Type SR750 protection relay. The incoming switchboard consists of (15) Square D Type VR vacuum circuit breakers protected by (15) GE Type SR350 protective relays. Backup power is provided by (2) 12.47kv generators. The generator switchboard consists of (5) 12.47kv Square D Type VR vacuum breakers Protective relays consist of (4) GE Type SR 489 relays and (1) GE Type SR 350 relay. There is one 125vdc battery backup system that consists of (60) Alpha Tab Type 50P25350 batteries, and 130vdc battery charger There is (1) Square D Model 6 motor control center (3 spare) Square D Type VR vacuum circuit breakers protected by (15) GE Type SR350 protective relays. Bldg. 28 Powerhouse Generator switchgear consists of: One Asco 7000 series automatic transfer switch One Westinghouse 800 amp main breaker One main service disconnect Square D 800 amp Bldg. 99 Infirmary Generator switchgear consists of: One Kohler model K166341-400 Transfer switch One Kohler model K166341-150 Transfer switch Two Kohler model K166341-70 Transfer switch Throughout facility 30 Federal Pacific Pad mounted non-automatic transfer switches 30 Howard Industries pad mounted Oil Filled transformers Timeline of Project S.O.W. to be completed in maximum of 6 working days. Monday-Friday (Saturday if needed). 5 consecutive workings with a 6th day as an option if needed. Stages 2-4 days are set Stages 5-7 can be combined as needed to complete in two working days Stage 1 Background checks submitted minimum of 3 weeks prior Stage 2 On Site fingerprints & badging completed on a Wednesday prior stage 2 Stage 2 Monday Working time 6am-2pm Stage 16 Generators with locking fuel caps and locking doors 13 inside the fence in secure areas 3 outside the fence Stage 3 Tuesday 4am… Expected Duration of loss of power 6 hours total both buildings • Service both High Voltage Switches and related equipment powered by Section 15 (2 switches total) o Bldg. 99 Switch Gear Service (3 switches), Provide Temporary Generator 150KW power for building ▪ Generator connection can be as early as 4am. ▪ Back on Utility when okayed by security. ▪ Complete Manual mode run of switch gear to verify proper transition operation. Length of full load test ½ hour. o Bldg. 8 Service High Voltage switch and manual transfer switch. Provide temporary power 150KW Generator staged out at transfer switch.(to power arsenal) ▪ Generator connection between 4am-5am ▪ Back on Utility when okayed by security o Bldg. 28 Switch Gear Service, Service High Voltage switch, Provide Temporary Generator 150KW power for building (to supply power for Fence equipment and security repeater) ▪ Generator connection after sunrise to maintain security lights ▪ Back on Utility when okayed by security ▪ Complete Manual mode run of switch gear to verify proper transition operation. Length of full load test ½ hour. Stage 4 Wednesday 12am…. Expected duration of loss of power 14 hours Main Switch Gear power shutdown & service (Power off after sunrise and power must be restored to main switch gear before sunset) All 16 buildings powered by portable generators will have power restored preferably before 6:00pm, power may be restored earlier or later upon security approval. Service High Voltage switch powered by section 9 Service 4 High Voltage switches powered by Section 11. (Section 11 can be added to different stage if there is not enough time to complete during Stage 4 ). Complete an Automatic and Manual mode run of switch gear to verify proper transition operation. Length of full load test ½ hour each mode. Stage 5 • 7 Portable Generators needed • Switch Gear Section 13 powered off after sunrise • Service 9 High Voltage switches Powered by that section. • Bldg. 99 will be powered by its stationary generator • Provide Temporary Generator power to 7 buildings inside the fence. • Bldg. 99 Infirmary will run on its Stationary Generator • One building without power. Stage 6 • 5 Portable Generators needed • Switch Gear Section 14 powered off after sunrise • Service 6 High Voltage switches Powered by that section. • Provide Temporary Generator power to 5 buildings inside the fence. • One building will be without power. Stage 7 • 4 Portable Generators needed • Switch Gear Section 10 powered off after sunrise • Service 8 High Voltage switches Powered by that section. • Provide Temporary Generator power to 4 buildings • 4 buildings will be without power. All equipment is to be serviced using this listed scope of work. Portable Generators 16 Portable Generators 14 - 150KW 2 - 300KW Contractor to provide generators, place generators and connect to critical buildings to maintain power during service, may have to be done during off hours. To be coordinated by the facility. All Generators will arrive full of fuel by the Contractor. The Facility will fill the generators as needed during the project and at the end of the project. Bldg. 108 Main switch gear to be serviced in one workday. Power off between Sunrise – Sunset daily or generator power supplied to all building before and after dark. Ensure proper operation of all equipment/all power restored prior to leaving every workday. All work must be bid using prevailing wage rate. SOW INCLUDES: Testing, maintenance, and Partial Discharge of 15kV vacuum circuit breakers, protective relays, transfer switches, facility transformers, battery banks and chargers, analog metering systems, and visual inspections of electrical distribution systems across multiple facility buildings. The project also includes providing and operating portable generators to maintain critical facility operations during scheduled outages, support for outage coordination and temporary power connection. Installing UL-listed infrared windows in incoming switchgear In addition, the contract requires delivery of Arc Flash Safety Awareness Training in accordance with the Occupational Safety and Health Administration and the National Fire Protection Association 70E (2024), along with Portable Generator Connection Training for facility personnel. ----------------------------------------------------------------------------------- KEY DETAILS: As the prime contractor, we are seeking certified partners to support project execution and help meet the contract participation goals. MBE Goal: 0.00% WBE Goal: 0.00% SDVOB: 6.00% If you are a NYS–certified SDVOB firm interested in partnering with us, please contact: Nhan Le (Mr.) – Proposal Director, LND Technical ServicesPhone: (615) 556-3090 | Email: [email protected] Service-Disabled Veteran-Owned Business (SDVOB) SDVOB Goal: 6.00% Minority / Women Business Enterprise contracting goals (MWBE) MBE Goal: 0.00% WBE Goal: 0.00% Disadvantaged Business Enterprise contracting goals (DBE) DBE Goal: 0.00%

Attached files

The solicitation documents live at the source — open the bid source above to download them.

Contact

Nhan Le(Proposal Director)

[email protected]

(615) 556-3090

Key dates

Opened
9/9/2026
Closes
10/2/2026
Duration
6 days

Last updated

Details

Type
Request for Qualification
Industry
Engineering Services
NAICS
541330
Solicitation №
2138836

Budget estimate

$150,000 – $300,000

The solicitation does not disclose a contract value. Based on typical rates for prevailing‑wage electrical testing, generator rental, and training services in New York State, a six‑day effort involving multiple high‑voltage systems and portable generators would likely fall between $150,000 and $300,000. Factors influencing the final amount include the number of generators supplied, overtime or off‑hour work, and any additional training or safety documentation required.

AI estimate from the solicitation

Similar opportunities

Matched by Bid Banana AI™

Bid Banana · 1.6M+ bids and awards 🍌

You found this one too late. Don't find the next one too late.

Bid Banana searches open government bids across all 50 states, updated daily. Save a search once and we email you your new matches, daily or weekly, while there is still time to win them.

1.6M+
bids & awards
All 50
states
4,000+
agencies
Start your 7-day free trial

Plans from $49.99/month. Cancel anytime, no setup fees.

Built by The Bid Lab, answering RFPs since 2017.

Corrections and Community Supervision, NYS Dept. of·New York

Top match · 78%

Electrical Switchgear Testing Washington Correctional

Closes 1/7/2027Opened 9/18/2026

Corrections and Community Supervision, NYS Dept. of·New York

75% match

ARC FLASH - Switchgear

Closes 11/19/2026Opened 10/28/2026

Corrections and Community Supervision, NYS Dept. of·New York

72% match

Electrical switchgear maintenance and Partial discharge testing

Closes 11/18/2026Opened 7/28/2026

U.S. Department Of Homeland Security·Connecticut

71% match

Inspect and Repair of 13.2KV Main Switchgear

Closes 11/12/2026Opened 10/30/2026

Corrections and Community Supervision, NYS Dept. of·New York

71% match

Switchgear Cleaning/Testing and Partial Discharge Testing

Closes 11/4/2026Opened 9/1/2026

Georgia Clayton County Water Authority·Georgia

70% match

2026-GS-14 Switchgear Preventative Maintenance and Overload Testing

Closes 11/12/2026Opened 10/15/2026

NYS OGS Design & Construction - Construction Contractors·New York

69% match

46151 E – Provide Switchgear & Control System Modification

Closes 11/4/2026Opened 9/23/2026

City of Tampa·Florida

69% match

Testing and Calibration of Paralleling Switchgear (Bid Discount)

Closes 11/9/2026Opened 10/9/2026

U.S. Department Of Veterans Affairs·New York

69% match

6640--Electrophoresis Testing for the Albany, Buffalo, and Syracuse VA Medical Centers

Closes 11/2/2026Opened 9/29/2026

NYS Seneca County·New York

68% match

Electronic Health Record (EHR) for Seneca County jail

Closes 11/6/2026Opened 10/16/2026

Corrections and Community Supervision, NYS Dept. of·New York

68% match

ARC FLASH

Closes 12/9/2026Opened 8/12/2026

U.S. Department Of Veterans Affairs·Illinois

67% match

657A5-26-111, Triennial Electrical Testing

Closes 11/9/2026Opened 10/9/2026

Los Angeles County Sanitation Districts·California

66% match

ELECTRICAL SERVICE AND SWITCHGEAR INSTALLATION — A. K. WARREN FACILITY BIOGAS CONDITIONING SYSTEM-2 (BCS-2)

Closes 11/16/2026Opened 10/20/2026

U.S. Department Of Veterans Affairs·Nevada

66% match

J061--Triennial Circuit Breaker and Feeder Testing

Closes 11/20/2026Opened 10/9/2026

U.S. Department Of Defense·Ohio

66% match

Repair Electrical Systems

Closes 11/12/2026Opened 10/1/2026

U.S. Department Of Defense·Ohio

66% match

Repair Electrical Systems

Closes 11/12/2026Opened 4/20/2026

Corrections and Community Supervision, NYS Dept. of·New York

66% match

Arc Flash Coordination Study

Closes 12/16/2026Opened 10/30/2026

State of Delaware OMB·Delaware

66% match

Morris Community Correction Center Generator & ATS Replacement

Closes 12/1/2026Opened 9/30/2026

NYS Matco Electric Corporation·New York

66% match

MBE/SDVOB Opportunity - Matco Electric Corporation

Closes 11/13/2026Opened 10/28/2026

California Department of Corrections and Rehabilitation·California

65% match

C5612448-D, Rebid 8 - High Voltage Equipment Maintenance and Repair Services

Closes 11/13/2026Opened 10/16/2026

U.S. Department Of Defense·United States of America

65% match

CIRCUIT BREAKER

Closes 11/2/2026Opened 10/1/2026

City of Sacramento·California

65% match

Electrical Studies for DOU Facilities

Closes 11/4/2026Opened 10/14/2026

Pennsylvania Department of Corrections·Pennsylvania

65% match

SCI Mercer - Medium Voltage Upgrades

Closes 12/1/2026Opened 10/14/2026

LA County Health Services·California

65% match

Equipment Maintenance and Repair (EMARS) - Electrical Distribution (RFR)

Rolling / TBD closeOpened 4/24/2018

Maryland 09001-GENERAL ADMINISTRATION - SPRINGFIELD HOSPITAL CENTER·Maryland

65% match

Springfield Hospital Center Preventive Maintenance and Load Testing of Fifteen (15) Emergency Generators 2026

Closes 11/13/2026Opened 10/29/2026