The City of Cincinnati, acting as agent for the Metropolitan Sewer District of Greater Cincinnati, is seeking qualified contractors to design and construct a 5,640‑ft dry‑weather flow channel (cunette) within the existing Combined Sewer 937, repair structural deficiencies, and install related flow‑control and access components. The work includes extensive concrete repair, excavation, back‑fill, traffic‑control, and final site restoration, all performed under strict environmental, safety, and Davis‑Bacon wage requirements.
• Install a 5,640‑ft concrete dry‑weather channel and tie‑ins to the Upper Muddy Creek Interceptor.
• Perform structural repairs to walls, floors, and roof of Sewer 937, including spall repair, reinforcement, and leak mitigation.
• Provide pre‑construction CCTV surveys, temporary bypass pumping, traffic‑control plans, erosion‑control, and post‑construction video documentation.
• Must meet a 5.4 % DBE participation goal, adhere to Buy‑America/Build‑America requirements, and provide a performance bond ≤ 1 % of the contract price.