The U.S. Army’s 127th Quartermaster Company seeks information on a deployable, climate‑controlled, externally ventilated HAZMAT storage system to safely house highly reactive water‑treatment chemicals. The system must be a three‑bay, 2‑hour fire‑rated metal container with integrated Class 1 Division 2 heat‑pump, explosion‑proof exhaust, secondary spill containment (≥ 551 gal), 45 lb dry‑chemical fire suppression, and a flexible power “whip cord” for generator or external source. Mobility is essential; the unit must be forklift/crane‑movable and ruggedized for tactical deployment. Respondents must provide detailed specifications, lead times, capability statements, and relevant NAICS codes.
• One 3‑bay, 25 × 7 × 9 ft container (U.S. Chemical Storage 2HRBFR)
• UL 263 / ASTM E‑119 2‑hour fire rating, weatherproof
• Integrated Class 1 Div 2 HVAC mini‑split (heating/cooling)
• Explosion‑proof mechanical exhaust with low‑floor intake
• 551‑gal secondary containment sump
• 45‑lb UL/ULC/FM‑approved dry‑chemical fire suppression system
• Ruggedized, forklift/crane‑compatible mobility
• “Whip cord” power interface for generators or external power
• Capacity for ≥ 36 drums (3‑bay design)