Bid Banana
PricingBid helpAPILog inStart free trial
Log inStart free trial

Learn more

  • Hawaii guideHawaii Bids and Bidding Guide
  • Construction RFPsConstruction Bids and Bidding Guide
  • How to answer an IFBInvitation for Bid: You Just Received an IFB, Now What?
More construction bids →Must-win bid? Bring in The Bid Lab →
Bid Banana
SearchPricingBid helpBrowse bidsAPISupportFAQPrivacy PolicyTerms of UseAI Use Policy

This website and its content is copyright of The Bid Lab © 2026. The Bid Lab is a trademark of Bid Lab, LLC. All rights reserved.

  1. Bid Banana
  2. ›Closed bids
  3. ›Hawaii
  4. ›Construction
  5. ›Furnish and Replace Emergency Standby 350kW Diesel…

County of Maui·Hawaii

Furnish and Replace Emergency Standby 350kW Diesel Generator and Associated Apparatus at North Waihee Booster Station

Closes 3/5/2026$500k – $1.5MInvitation for BidLogin required
Bid source

This opportunity has closed.

Bid Banana tracks 1.6M+ bids and awards across all 50 states. Save a search and we'll email your new matches, daily or weekly — so the next one reaches you with time to bid.

Get alerted next time

Description

The County of Maui, Department of Water Supply, is seeking bids for the furnishing and replacement of an emergency standby 350kW diesel generator and associated apparatus at the North Waihee Booster Station. The project includes the removal of the existing generator, automatic transfer switch, and appurtenances, and the installation of a new 350 kW standby diesel generator, 480V, 3-phase, 60 Hz, with a new automatic transfer switch and triple mode switch. The successful bidder will be required to provide startup testing, load-bank testing, training, and O&M documentation. • The generator set must be rated for 350 kW, 60 Hz, 1800 RPM, 480V, 3-phase, with an EPA-certified stationary emergency diesel engine and a 4-pole, PMG excitation alternator. • The automatic transfer switch must be UL-1008 listed, 400A, 480V, 3-phase, service entrance rated, with open-transition, digital controls, test functions, time delays, utility and generator sensing, and remote annunciation contacts. • The triple mode switch must be an ESL Power Systems Triple Switch or pre-approved equal, with a rating of 600A, and features including disconnect aux contact, phase rotation monitor, and optional pilot lights. • The project requires a sub-base fuel tank with a capacity of 660 gallons, and a UL-142 double-wall stainless-steel sub-base tank with rupture basin, emergency venting, and leak detection. • The successful bidder must provide a manufacturer's standard warranty or 1 year, starting from project completion date, and provide startup and testing, load-bank test, training, and O&M documentation.

Attached files

The solicitation documents live at the source — open the bid source above to download them.

Contact

Ashley DeCastro(Procurement Contact)

[email protected]

(808) 270-7680

Key dates

Opened
1/20/2026
Pre-bid meeting
2/11/2026
Site visit
2/11/2026
Closes
3/5/2026
Duration
630 days

Last updated

Details

Type
Invitation for Bid
Industry
Construction
NAICS
237130
Solicitation №
DWSP 2026-14

Budget estimate

$500,000 – $1,500,000

The budget for this project is estimated to be between $500,000 and $1,500,000, based on the scope of work and industry standards for similar projects. The factors influencing this estimate include the cost of the new diesel generator, automatic transfer switch, and triple mode switch, as well as the cost of labor, materials, and equipment for the installation and testing of the new equipment.

AI estimate from the solicitation

Similar opportunities

Matched by Bid Banana AI™

Bid Banana · 1.6M+ bids and awards 🍌

You found this one too late. Don't find the next one too late.

Bid Banana searches open government bids across all 50 states, updated daily. Save a search once and we email you your new matches, daily or weekly, while there is still time to win them.

1.6M+
bids & awards
All 50
states
4,000+
agencies
Start your 7-day free trial

Plans from $49.99/month. Cancel anytime, no setup fees.

Built by The Bid Lab, answering RFPs since 2017.

Village of Key Biscayne·Florida

Top match · 73%

Key Biscayne Community Center Emergency Generator

Closes 11/9/2026Opened 9/23/2026

Clark County·Nevada

72% match

Fire Station 71 Bunkerville Emergency Generator Connection

Closes 12/3/2026Opened 10/26/2026

Town of Narragansett·Rhode Island

72% match

Stand-by Generator Replacement - WWTP

Closes 11/6/2026Opened 11/6/2026

Town of Tyrone·Georgia

72% match

2026 Generator Replacement Sewer Pump Station #3

Closes 11/4/2026Opened 10/5/2026

State of Delaware OMB·Delaware

71% match

Prickett Building Generator Replacement

Closes 11/24/2026Opened 10/8/2026

U.S. Department Of Defense·United States of America

71% match

Replace DSN-HDD Generator for 78th Signal Battalion, Camp Zama, Japan.

Closes 11/9/2026Opened 10/18/2026

City of Rockford·Illinois

71% match

EMERGENCY GENERATOR REPLACEMENT AT FIRE STATION 8 AND NEWBURG RD. TRANSMITTER SITE

Closes 11/12/2026Opened 10/16/2026

Jefferson Parish Sheriff's Office·Louisiana

70% match

25-NOV-2501 New Diesel Generator

Closes 11/25/2026Opened 10/28/2026

Wyoming Department of Transportation·Wyoming

70% match

GENERATOR REPLACEMENT

Closes 11/10/2026Opened 10/9/2026

City of Lynn Haven·Florida

70% match

Generator Maintenance

Closes 11/16/2026Opened 10/26/2026

County of Maui·Hawaii

70% match

Furnish and Delivery of One (1) 100kW Portable Diesel Generator System

Closes 11/10/2026Opened 10/9/2026

Somerset County·New Jersey

70% match

Emergency and Non-Emergency Repairs for Gasboy Island Fuel Management System

Closes 11/24/2026Opened 10/26/2026

Lucas County, OH Facility Management·Ohio

70% match

CIP 26-011 EMS Generator

Closes 11/12/2026Opened 10/9/2026

NYS OGS Design & Construction - Construction Contractors·New York

70% match

Replace Electrical Panels – Electrical Panel Replacement and Generator Installation Project

Closes 11/18/2026Opened 10/13/2026

City of Tulsa·Oklahoma

69% match

Emergency Generator Cherry Creek Pump Station

Closes 11/18/2026Opened 10/21/2026

State of Delaware OMB·Delaware

69% match

Morris Community Correction Center Generator & ATS Replacement

Closes 12/1/2026Opened 9/30/2026

Jefferson Parish Sheriff's Office·Louisiana

69% match

New Diesel Generator

Closes 11/25/2026Opened 10/28/2026

City of Plant City·Florida

69% match

Plant City Utilities Communication Tower Generator Replacement (FEMA)

Closes 12/3/2026Opened 10/22/2026

Massachusetts Town of Natick·Massachusetts

69% match

IFB: Generator Maintenance, Repair, and Emergency Repair - 3 Years - Subject to Ann. Appropriation.

Closes 11/5/2026Opened 10/21/2026

Massachusetts Town of Danvers·Massachusetts

69% match

Endicott Street Generator Replacement

Closes 11/12/2026Opened 10/15/2026

New Jersey Division of Property Management and Construction (NJ DPMC)·New Jersey

68% match

Generator Replacement Project – Four NJDOT Maintenance Facilities

Closes 11/19/2026Opened 8/25/2026

U.S. Department Of Agriculture·Washington

68% match

Johnston Ridge Observatory Backup Generator Repairs Gifford Pinchot National Forest

Closes 11/3/2026Opened 10/20/2026

City of Memphis·Tennessee

68% match

Generator Service for General Services

Closes 11/4/2026Opened 10/16/2026

City of Mexico Beach·Florida

68% match

Purchase & Installation of s 48-kW Deisel Generator

Closes 11/16/2026Opened 10/19/2026

City of Davenport·Iowa

68% match

Generator Services

Closes 11/12/2026Opened 10/26/2026