Bid Banana
PricingBid helpAPILog inStart free trial
Log inStart free trial

Learn more

  • Ohio guideOhio Bids and Bidding Guide
  • Pricing your quoteWhy Your RFP Pricing Strategy Is Costing You
  • How to answer an RFQRFQ Meaning: What Is an RFQ?
More engineering services bids →Must-win bid? Bring in The Bid Lab →
Bid Banana
SearchPricingBid helpBrowse bidsAPISupportFAQPrivacy PolicyTerms of UseAI Use Policy

This website and its content is copyright of The Bid Lab © 2026. The Bid Lab is a trademark of Bid Lab, LLC. All rights reserved.

  1. Bid Banana
  2. ›Closed bids
  3. ›Ohio
  4. ›Engineering Services
  5. ›711-MLG-GENERATORSERVICE/MOORE

Ohio·Ohio

711-MLG-GENERATORSERVICE/MOORE

Closes 10/6/2026$2k – $5kRequest for Quotation
Bid source

This opportunity has closed.

Bid Banana tracks 1.6M+ bids and awards across all 50 states. Save a search and we'll email your new matches, daily or weekly — so the next one reaches you with time to bid.

Get alerted next time

Description

The solicitation calls for a full‑service, two‑hour load‑bank test on three on‑site generators located in Building 18 (Kohler 230ROZD75), Building 6 (Cat 1000SR4) and the TCC building (Onan 500DFEK) at the Trumbull Correctional Institution. The contractor must provide all equipment, personnel, and reporting required for the load‑bank testing, following the attached scope of work. This is a quick‑quote, open‑bid procurement with a tight deadline. • Perform a 2‑hour load‑bank test on each of three generators (total ~6 hours of work). • Deliver full test reports and any required certification per the attached scope. • Work must be completed at the Trumbull Correctional Institution warehouse (Leavittsburg, OH) before the bid deadline of 10 Oct 2026.

Attached files

The solicitation documents live at the source — open the bid source above to download them.

Contact

Mr. Moore

(234) 308-6521

Key dates

Opened
9/21/2026
Questions due
10/5/2026
Closes
10/6/2026
Duration
2 hours

Last updated

Details

Type
Request for Quotation
Industry
Engineering Services
NAICS
541380
Solicitation №
SRC0000042031

Budget estimate

$2,000 – $5,000

Based on typical rates for load‑bank testing (approximately $250‑$500 per hour per generator) plus travel and reporting costs, the total contract value is estimated between $2,000 and $5,000. The lower bound assumes minimal travel and a simple report; the higher bound includes additional documentation, potential overtime, and equipment mobilization.

AI estimate from the solicitation

Similar opportunities

Matched by Bid Banana AI™

Bid Banana · 1.6M+ bids and awards 🍌

You found this one too late. Don't find the next one too late.

Bid Banana searches open government bids across all 50 states, updated daily. Save a search once and we email you your new matches, daily or weekly, while there is still time to win them.

1.6M+
bids & awards
All 50
states
4,000+
agencies
Start your 7-day free trial

Plans from $49.99/month. Cancel anytime, no setup fees.

Built by The Bid Lab, answering RFPs since 2017.

U.S. Department Of Defense·Oklahoma

Top match · 68%

Generator, Direct Cu

Closes 10/14/2027Opened 10/14/2026

U.S. Department Of Defense·United States of America

68% match

61--GENERATOR,ALTERNATING

Closes 11/4/2026Opened 10/25/2026

U.S. Department Of Defense·Washington

68% match

750kW Emergency Diesel Generator (EDG) Rental (PSNS&IMF)

Closes 11/5/2026Opened 10/23/2026

City of Memphis·Tennessee

68% match

Generator Service for General Services

Closes 11/4/2026Opened 10/16/2026

U.S. Department Of Defense·United States of America

67% match

16--GENERATOR,VARIABLE, IN REPAIR/MODIFICATION OF

Closes 12/1/2026Opened 8/18/2026

U.S. Department Of Defense·Pennsylvania

67% match

61 - FMS REPAIR - GENERATOR, ALTER

Closes 11/10/2026Opened 10/26/2026

NYS Brookhaven, Town of·New York

67% match

Installation of Generators at Various Town Locations

Closes 11/13/2026Opened 10/26/2026

Jefferson Parish Sheriff's Office·Louisiana

67% match

New Diesel Generator

Closes 11/25/2026Opened 10/28/2026

U.S. Department Of Defense·Utah

67% match

GENERATOR, SIGNAL

Closes 11/17/2027Opened 11/18/2022

U.S. Department Of Defense·United States of America

66% match

61--GENERATOR,ALTERNATI, IN REPAIR/MODIFICATION OF

Closes 11/23/2026Opened 10/23/2026

Central Ohio Transit Authority (COTA)·Ohio

66% match

Generator PM & On Call Services for COTA Facilities

Closes 11/10/2026Opened 10/20/2026

U.S. Department Of Defense·United States of America

66% match

Generator, Direct CU

Closes 12/18/2026Opened 10/29/2026

City of Davenport·Iowa

66% match

Generator Services

Closes 11/12/2026Opened 10/26/2026

City of Columbia·Missouri

66% match

Power Plant Emergency Generator

Closes 11/17/2026Opened 10/26/2026

Texas Department of Transportation·Texas

66% match

Statewide Generator Inspection, Repair, and Preventive Maintenance Services

Closes 11/16/2026Opened 10/16/2026

City of Lake Charles·Louisiana

66% match

CITY OF LAKE CHARLES, LOUISIANA HAZARD MITIGATION GRANT PROGRAM (HMGP) LIFT STATION BACK‑UP POWER IMPROVEMENTS

Closes 11/17/2026Opened 10/22/2026

Village of Oak Brook·Illinois

66% match

2026 Annual Generator Maintenance Service

Closes 11/10/2026Opened 10/27/2026

U.S. Department Of Defense·United States of America

66% match

61--GENERATOR,ALTERNATI, IN REPAIR/MODIFICATION OF

Closes 11/22/2026Opened 10/7/2026

Alabama Houston County Health Department·Alabama

66% match

271982 - Generator Monitoring - Houston Co Health Dept

Closes 11/2/2026Opened 10/28/2026

Mississippi Alcorn State University·Mississippi

66% match

Generator Project – Walter Washington, Simmons Gym, and Rowan Nursing

Closes 11/12/2026Opened 10/9/2026

U.S. Department Of Health And Human Services·Oklahoma

66% match

Emergency Generator Preventive Maintenance, Repair, Emergency Callout & Rental Services

Closes 11/6/2026Opened 10/28/2026

U.S. Department Of Defense·California

66% match

29--GENERATOR,ENGINE ACCES

Closes 11/8/2026Opened 10/29/2026

U.S. Department Of Defense·United States of America

65% match

GENERATOR, ALTERNATING

Closes 11/2/2026Opened 10/19/2026

U.S. Department Of Defense·Maryland

65% match

Diesel Engine, Starter Motor, Magnetic Contactors, Powerpack & Alternators Supporting 800kW, 60 Hz DPGDS - Non-Commercial NSN's

Closes 11/9/2026Opened 10/8/2026

U.S. Department Of Defense·Pennsylvania

65% match

16--GENERATOR,VARIABLE, IN REPAIR/MODIFICATION OF

Closes 12/3/2026Opened 8/18/2026