Bid Banana
PricingBid helpAPILog inStart free trial
Log inStart free trial

Learn more

  • California guideCalifornia Bids and Bidding Guide
  • Construction RFPsConstruction Bids and Bidding Guide
  • How to answer an IFBInvitation for Bid: You Just Received an IFB, Now What?
More construction bids →Must-win bid? Bring in The Bid Lab →
Bid Banana
SearchPricingBid helpBrowse bidsAPISupportFAQPrivacy PolicyTerms of UseAI Use Policy

This website and its content is copyright of The Bid Lab © 2026. The Bid Lab is a trademark of Bid Lab, LLC. All rights reserved.

  1. Bid Banana
  2. ›Closed bids
  3. ›California
  4. ›Construction
  5. ›2CA07605 Install Generator, Automatic Transfer Switch, and…

California Department of Forestry and Fire Protection·California

2CA07605 Install Generator, Automatic Transfer Switch, and CamLok

Closes 5/6/2026$200k – $600kInvitation for Bid
Bid source

This opportunity has closed.

Bid Banana tracks 1.6M+ bids and awards across all 50 states. Save a search and we'll email your new matches, daily or weekly — so the next one reaches you with time to bid.

Get alerted next time

Description

The California Department of Forestry and Fire Protection (CAL FIRE) is seeking a qualified electrical contractor to supply and install a standby diesel generator, an automatic transfer switch (ATS), a manual transfer switch (MTS), and a CamLok quick‑connect locking system at the Happy Valley Fire Center in Redding, CA. The contractor must provide all materials, labor, permits, testing, commissioning, training, and one‑year warranty, and must meet CAL FIRE’s electrical, safety, and code requirements. The project includes demolition of existing equipment, site work (concrete pads, conduit, grounding, and bonding), coordination with PG&E, and full system testing in the presence of the State Fire Marshal. • Supply and install a 30 kW or 150 kW standby diesel generator with associated ATS and CamLok system. • Provide all associated switchboards, conduit, grounding, strip heaters, and site‑preparation work, including concrete pads and protective bollards. • Complete testing, commissioning, on‑site training (minimum 8 hours), and deliver as‑built documentation and a one‑year warranty.

Attached files

Contact

Christopher Cabanes(Contracts Analyst)

[email protected]

(916) 653-7772

Key dates

Opened
4/2/2026
Questions due
4/17/2026
Pre-bid meeting
4/14/2026Mandatory
Site visit
4/14/2026Mandatory
Closes
5/6/2026
Duration
12 months

Last updated

Details

Type
Invitation for Bid
Industry
Construction
NAICS
238210
Solicitation №
2CA07605

Budget estimate

$200,000 – $600,000

The solicitation does not disclose a contract ceiling. Similar CAL FIRE generator‑installation projects for a 30‑150 kW standby system, including full electrical work, typically range from $200,000 to $600,000 depending on equipment choice, site conditions, and labor rates. Therefore a reasonable estimate for the award value is between $200K and $600K.

AI estimate from the solicitation

Similar opportunities

Matched by Bid Banana AI™

Bid Banana · 1.6M+ bids and awards 🍌

You found this one too late. Don't find the next one too late.

Bid Banana searches open government bids across all 50 states, updated daily. Save a search once and we email you your new matches, daily or weekly, while there is still time to win them.

1.6M+
bids & awards
All 50
states
4,000+
agencies
Start your 7-day free trial

Plans from $49.99/month. Cancel anytime, no setup fees.

Built by The Bid Lab, answering RFPs since 2017.

New Orleans Regional Transit Authority·Louisiana

Top match · 66%

Installation of Transfer Switches & Emergency Generator

Closes 11/11/2026Opened 9/14/2026

U.S. Department Of Justice·Texas

65% match

Install Generator- FCI Bastrop

Closes 12/2/2026Opened 10/23/2026

City of Clermont·Florida

64% match

Well House Generator Transfer Switch Improvements

Closes 11/12/2026Opened 10/16/2026

NYS OGS Design & Construction - Construction Contractors·New York

62% match

Replace Electrical Panels – Electrical Panel Replacement and Generator Installation Project

Closes 11/18/2026Opened 10/13/2026

Texas Tx Dept Crim. Justice/inst Div·Texas

62% match

Installation of State-Owned Equipment, Generator & ATS

Closes 12/1/2026Opened 10/23/2026

Clark County·Nevada

62% match

Fire Station 71 Bunkerville Emergency Generator Connection

Closes 12/3/2026Opened 10/26/2026

U.S. Department Of Agriculture·California

62% match

Removal, Repair, Reinstallation of Winco LP Standby Generator, Sixs Rivers NF

Closes 11/11/2026Opened 10/29/2026

City of Lake Charles·Louisiana

62% match

CITY OF LAKE CHARLES, LOUISIANA HAZARD MITIGATION GRANT PROGRAM (HMGP) LIFT STATION BACK‑UP POWER IMPROVEMENTS

Closes 11/17/2026Opened 10/22/2026

Town of Tyrone·Georgia

61% match

2026 Generator Replacement Sewer Pump Station #3

Closes 11/4/2026Opened 10/5/2026

U.S. Department Of Defense·United States of America

61% match

16--GENERATOR,VARIABLE, IN REPAIR/MODIFICATION OF

Closes 12/1/2026Opened 8/18/2026

U.S. Department Of Defense·United States of America

61% match

GENERATOR, ALTERNATING

Closes 11/2/2026Opened 10/19/2026

U.S. Department Of Defense·United States of America

61% match

Transfer Transmission

Closes 11/17/2026Opened 10/27/2026

U.S. Department Of Defense·Oklahoma

61% match

Generator, Direct Cu

Closes 10/14/2027Opened 10/14/2026

Village of Key Biscayne·Florida

61% match

Key Biscayne Community Center Emergency Generator

Closes 11/9/2026Opened 9/23/2026

State of Oklahoma, Division of Capital Assets Management, Construction & Properties·Oklahoma

61% match

CAP26-0384 Standby Generator Installation Project

Closes 11/24/2026Opened 10/23/2026

U.S. Department Of Defense·United States of America

61% match

61--GENERATOR,ALTERNATI, IN REPAIR/MODIFICATION OF

Closes 11/22/2026Opened 10/7/2026

National Aeronautics And Space Administration·United States of America

60% match

TECHNOLOGY TRANSFER OPPORTUNITY: Universal Power Converter for a Lunar Power Grid (LEW-TOPS-181)

Closes 8/24/2027Opened 8/24/2026

Wyoming Department of Transportation·Wyoming

60% match

GENERATOR REPLACEMENT

Closes 11/10/2026Opened 10/9/2026

Kenai Peninsula Borough·Alaska

60% match

ITB27-026 South Peninsula Hospital Generator

Closes 11/3/2026Opened 10/7/2026

U.S. Department Of Defense·Michigan

60% match

COMMON ETHERNET SWITCH CONTAINER

Closes 11/13/2026Opened 9/1/2026

Iowa State University·Iowa

60% match

CP1269515-Utilities-Pearson Substation-4.16kV Switchgear and Cable Infrastructure Upgrade

Closes 11/3/2026Opened 10/6/2026

U.S. Department Of Defense·Utah

60% match

GENERATOR, SIGNAL

Closes 11/17/2027Opened 11/18/2022

City of Plant City·Florida

60% match

Plant City Utilities Communication Tower Generator Replacement (FEMA)

Closes 12/3/2026Opened 10/22/2026

U.S. Department Of Defense·Pennsylvania

60% match

61 - FMS REPAIR - GENERATOR, ALTER

Closes 11/10/2026Opened 10/26/2026

U.S. Department Of Defense·United States of America

60% match

58--CONTROL,CONVERTER

Closes 11/4/2026Opened 10/20/2026