Bid Banana
PricingBid helpAPILog inStart free trial
Log inStart free trial

Learn more

  • Federal contracts (SAM.gov)The Ultimate Guide to SAM.gov Registration
  • How to answer an RFIRFI Meaning: What Is an RFI?
More energy and utilities bids →Must-win bid? Bring in The Bid Lab →
Bid Banana
SearchPricingBid helpBrowse bidsAPISupportFAQPrivacy PolicyTerms of UseAI Use Policy

This website and its content is copyright of The Bid Lab © 2026. The Bid Lab is a trademark of Bid Lab, LLC. All rights reserved.

  1. Bid Banana
  2. ›Closed bids
  3. ›Federal
  4. ›J059--SOURCES SOUGHT NOTICE SWITCHGEAR MAINTENANCE TESTING…

U.S. Department Of Veterans Affairs·Maryland

J059--SOURCES SOUGHT NOTICE SWITCHGEAR MAINTENANCE TESTING SERVICES BALTIMORE VA MEDICAL CENTER 36C24526Q0196

Closes 1/12/2026$50k – $200kRequest for Information
Bid source

This opportunity has closed.

Bid Banana tracks 1.6M+ bids and awards across all 50 states. Save a search and we'll email your new matches, daily or weekly — so the next one reaches you with time to bid.

Get alerted next time

Description

The Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5 is seeking sources for switchgear maintenance testing services at the Baltimore VA Medical Center. The contractor will be required to perform NETA Maintenance Testing and inspection services on the GE PowerVac 15KV Switchgear Lineup. The scope of work includes visual and mechanical inspections, cleaning and torqueing of electrical connections, insulation resistance testing, contact resistance testing, and other tasks. The contractor must provide all necessary test equipment, tools, and safety gear, and ensure that all instruments are calibrated and traceable to NIST standards. The contractor must also comply with all facility safety and security procedures. Some key points to consider include: • The contractor must provide a qualified NETA-certified technician to perform the testing. • The contractor must submit a proposed testing plan and timeline for approval no later than 10 business days prior to mobilization. • The contractor must provide all necessary test equipment, tools, and safety gear. • The contractor must ensure that all instruments are calibrated and traceable to NIST standards. • The contractor must comply with all facility safety and security procedures.

Attached files

Contact

Bill Pratt(Contracting Officer)

[email protected]

(410) 642-2411

Key dates

Opened
12/29/2025
Closes
1/12/2026

Last updated

Details

Type
Request for Information
Industry
Energy and Utilities
NAICS
238210
Solicitation №
36C24526Q0196

Budget estimate

$50,000 – $200,000

The budget for this opportunity is difficult to estimate, as it is a sources sought notice and not a solicitation. However, based on the scope of work, it is likely that the contract value will be in the range of $50,000 to $200,000. The factors that may influence the likely payment range include the complexity of the testing and inspection services, the number of personnel required to perform the work, and the duration of the contract.

AI estimate from the solicitation

Similar opportunities

Matched by Bid Banana AI™

Bid Banana · 1.6M+ bids and awards 🍌

You found this one too late. Don't find the next one too late.

Bid Banana searches open government bids across all 50 states, updated daily. Save a search once and we email you your new matches, daily or weekly, while there is still time to win them.

1.6M+
bids & awards
All 50
states
4,000+
agencies
Start your 7-day free trial

Plans from $49.99/month. Cancel anytime, no setup fees.

Built by The Bid Lab, answering RFPs since 2017.

U.S. Department Of Veterans Affairs·West Virginia

Top match · 84%

J061--SOURCES SOUGHT NOTICE - Triennial Electrical Inspection Testing and Maintenance Services Requirement - Louis A Johnson VA Medical Center 36C24527Q0039

Closes 11/5/2026Opened 10/20/2026

U.S. Department Of Veterans Affairs·Texas

78% match

L063-- Physical Security Equipment Maintenance and Testing

Closes 11/5/2026Opened 10/29/2026

U.S. Department Of Veterans Affairs·Illinois

77% match

657A5-26-111, Triennial Electrical Testing

Closes 11/9/2026Opened 10/9/2026

U.S. Department Of Veterans Affairs·Maryland

77% match

J044--NOTICE OF INTENT TO SOLE SOURCE Baltimore VAMC Steam System Preventive Maintenance from Vicinity Energy Baltimore Corporation

Closes 11/10/2026Opened 10/28/2026

Georgia Clayton County Water Authority·Georgia

77% match

2026-GS-14 Switchgear Preventative Maintenance and Overload Testing

Closes 11/12/2026Opened 10/15/2026

U.S. Department Of Veterans Affairs·Pennsylvania

76% match

J063--Security Access Control and Video Surveillance Systems Maintenance.

Closes 11/5/2026Opened 10/30/2026

U.S. Department Of Veterans Affairs·Nevada

75% match

J061--Triennial Circuit Breaker and Feeder Testing

Closes 11/20/2026Opened 10/9/2026

U.S. Department Of Defense·Maryland

74% match

Security Gate Maintenance and Repair Services Aberdeen Test Center, Aberdeen Proving Ground, MD

Closes 11/2/2026Opened 10/23/2026

Maryland 09001-GENERAL ADMINISTRATION - SPRINGFIELD HOSPITAL CENTER·Maryland

74% match

Springfield Hospital Center Preventive Maintenance and Load Testing of Fifteen (15) Emergency Generators 2026

Closes 11/13/2026Opened 10/29/2026

U.S. Department Of Veterans Affairs·New York

74% match

J065--Philips Imaging Equipment Service Maintenance NYH

Closes 11/4/2026Opened 10/28/2026

U.S. Department Of Homeland Security·Connecticut

74% match

Inspect and Repair of 13.2KV Main Switchgear

Closes 11/12/2026Opened 10/30/2026

U.S. Department Of Defense·United States of America

74% match

59--MAINTENANCE KIT,ELECTR

Closes 11/1/2026Opened 10/21/2026

U.S. Department Of Veterans Affairs·Louisiana

74% match

J061--TRIENNIAL ELECTRICAL MAINTENANCE - AMENDMENT 4 POP: 12/01/2026 - 11/30/2027 PLUS 4 OPTION YEARS

Closes 11/9/2026Opened 9/30/2026

Corrections and Community Supervision, NYS Dept. of·New York

74% match

Electrical switchgear maintenance and Partial discharge testing

Closes 11/18/2026Opened 7/28/2026

U.S. Department Of Homeland Security·District of Columbia

74% match

Request for Information (RFI) - CONUS Generator Maintenance

Closes 11/5/2026Opened 10/15/2026

U.S. Department Of Veterans Affairs·Indiana

74% match

J065--Imaging Service & Preventative Maintenance EHCC & MTV

Closes 11/2/2026Opened 10/21/2026

Corrections and Community Supervision, NYS Dept. of·New York

74% match

Electrical Switchgear Testing Washington Correctional

Closes 1/7/2027Opened 9/18/2026

U.S. Department Of Defense·Ohio

73% match

Repair Electrical Systems

Closes 11/12/2026Opened 10/1/2026

U.S. Department Of Defense·United States of America

73% match

36--ECG REFURBISH KIT

Closes 12/10/2026Opened 10/27/2026

Corrections and Community Supervision, NYS Dept. of·New York

73% match

Switchgear Cleaning/Testing and Partial Discharge Testing

Closes 11/4/2026Opened 9/1/2026

U.S. Department Of Defense·United States of America

73% match

59--MATCHED SET,ELECTRO, IN REPAIR/MODIFICATION OF

Closes 11/23/2026Opened 10/22/2026

U.S. Department Of Defense·Ohio

73% match

Repair Electrical Systems

Closes 11/12/2026Opened 4/20/2026

U.S. Department Of Defense·District of Columbia

73% match

Request for Information/Market Intelligence Notice: Repair Electrical Distribution System Switchgear Stations & Addition of Redundancy Cable Use of Progressive Design Build (PDB) with Other Transaction Authority (OTA)

Closes 11/30/2026Opened 10/23/2026

U.S. Department Of Defense·United States of America

73% match

Werfen/Instrumentation Laboratories Equipment Maintenance & Supplies

Closes 11/12/2026Opened 10/27/2026

Virginia Department of Transportation·Virginia

72% match

UIFB 161283 Electrical Maintenance & Repair

Closes 11/2/2026Opened 10/28/2026