The Department of Veterans Affairs is conducting market research to assess industry capability to supply and install patient‑safety ceiling lift systems at the White River Junction VA Medical Center. The solicitation seeks detailed information on manufacturers, installers, and service providers that can meet extensive technical specifications, including ISO 10535:2021 compliance, load capacities of 550 lb and 825 lb, optional horizontal motor traverse, Wi‑Fi integration, and specific battery and noise requirements. The scope also includes installation in 21 rooms, removal of 18 existing lifts, provision of engineering calculations, slings, and user training. Respondents must be SAM‑registered; SDVOSBs must also hold SBA Vet Cert. No proposals will be accepted and no contract will be awarded from this notice.
• Required equipment: ceiling‑mounted lifts, aluminum linear tracks (3 m, 4 m, 6 m), 550 lb & 825 lb lift supports, medium hanger bars, trainer module motor, disposable slings, and related accessories.
• Quantities total 21 lift systems, various track lengths, 84 slings, and full installation/removal services.
• Technical specs include motor speed ≥ 60 mm/s, noise ≤ 60 dB(A), 24 V NiMH batteries (single or dual), Wi‑Fi data logging, LCD display, and compliance with infection‑control level II standards.