Bid Banana
PricingBid helpAPILog inStart free trial
Log inStart free trial

Learn more

  • Washington guideWashington Bids and Bidding Guide
  • Pricing your bidWhy Your RFP Pricing Strategy Is Costing You
  • How to answer an IFBInvitation for Bid: You Just Received an IFB, Now What?
More energy and utilities bids →Must-win bid? Bring in The Bid Lab →
Bid Banana
SearchPricingBid helpBrowse bidsAPISupportFAQPrivacy PolicyTerms of UseAI Use Policy

This website and its content is copyright of The Bid Lab © 2026. The Bid Lab is a trademark of Bid Lab, LLC. All rights reserved.

  1. Bid Banana
  2. ›Closed bids
  3. ›Washington
  4. ›Energy and Utilities
  5. ›Forks Substation 5MVA Transformer

PUD #1 of Clallam County·Washington

Forks Substation 5MVA Transformer

Closes 10/28/2025$500k – $2MInvitation for BidLogin required
Bid source

This opportunity has closed.

Bid Banana tracks 1.6M+ bids and awards across all 50 states. Save a search and we'll email your new matches, daily or weekly — so the next one reaches you with time to bid.

Get alerted next time

Description

The Public Utility District No. 1 of Clallam County is seeking bids for the purchase of one new, rebuilt, or reconditioned step-up transformer, 5MVA or larger, 12.47kV/29.94kV. The transformer should conform to the latest applicable IEEE, ANSI, and NEMA standards. The successful bidder will be required to provide a bid bond, certified check, or cashier's check in an amount equal to five percent of the bid. The contract will include provisions for payment, delivery, and warranty. • The transformer should be designed for outdoor use and have a 60 Hertz frequency. • The transformer should have a three-phase, oil-immersed design with a 55°C average winding temperature rise and an 80°C hot spot winding temperature rise. • The transformer should be rated for elevation up to 3,300 feet. • The transformer should have a high voltage of 24,940 Volts Wye and a low voltage of 12,470 Volts Wye. • The transformer should have a high voltage BIL of 150 kV and a low voltage BIL of 110 kV. • The transformer should have an impedance of 12,000 kV. • The contractor should provide a detailed dimensional drawing and design specifications for the construction of the transformer. • The contractor should provide a complete and detailed operation and maintenance manual, inspection manual, and test data for the transformer.

Attached files

Contact

Jenean Keate(Contracts Coordinator)

[email protected]

(360) 565-3243

Key dates

Opened
9/10/2025
Questions due
9/24/2025
Closes
10/28/2025

Last updated

Details

Type
Invitation for Bid
Industry
Energy and Utilities
NAICS
22112
Solicitation №
250807

Budget estimate

$500,000 – $2,000,000

The budget for this opportunity is estimated to be between $500,000 and $2,000,000, based on the cost of a 5MVA step-up transformer. The actual budget may vary depending on the bid price and the terms of the contract. Factors that may influence the budget include the cost of materials, labor, and transportation, as well as the complexity of the project and the level of competition among bidders.

AI estimate from the solicitation

Similar opportunities

Matched by Bid Banana AI™

Bid Banana · 1.6M+ bids and awards 🍌

You found this one too late. Don't find the next one too late.

Bid Banana searches open government bids across all 50 states, updated daily. Save a search once and we email you your new matches, daily or weekly, while there is still time to win them.

1.6M+
bids & awards
All 50
states
4,000+
agencies
Start your 7-day free trial

Plans from $49.99/month. Cancel anytime, no setup fees.

Built by The Bid Lab, answering RFPs since 2017.

Bristol Virginia Utilities Authority·Virginia

Top match · 62%

IFB 20261005 SUBSTATION TRANSFORMER

Closes 11/10/2026Opened 10/5/2026

City of Denton·Texas

61% match

Supply of Electric Utility Instrument Transformers

Closes 11/11/2026Opened 10/2/2026

City of St. Charles·Illinois

61% match

Substation Transformer Reconditioning - 3T3

Closes 11/20/2026Opened 10/28/2026

KC Board of Public Utilities·Kansas

60% match

Nearman N1 Generator Step Up Transformer

Closes 12/11/2026Opened 9/25/2026

U.S. Department Of Defense·Virginia

60% match

TRANSFORMER,POWER

Closes 11/6/2026Opened 10/16/2026

Tacoma·Washington

59% match

Husky Terminal 115KV BABA Transformer

Closes 12/8/2026Opened 10/30/2026

Rochester Public Utilities·Minnesota

58% match

Power Transformer - Zumbro River Substation

Closes 11/23/2026Opened 10/13/2026

U.S. Department Of Defense·Illinois

58% match

CSSC Utility Feed Transformer Replacement

Closes 11/5/2026Opened 10/27/2026

Hawaii Department of Defense·Hawaii

57% match

TRANSFORMER REPLACEMENT

Closes 11/19/2026Opened 10/19/2026

City of Lodi·California

57% match

Electric Utility- 230/60kV Auto Transformers

Closes 12/18/2026Opened 10/15/2026

U.S. Department Of Veterans Affairs·Pennsylvania

57% match

Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC

Closes 11/20/2026Opened 10/23/2026

U.S. Department Of Defense·Oklahoma

56% match

15kV Switchgear & Station Service Replacement at Lake Tenkiller, OK

Closes 11/10/2026Opened 10/27/2026

U.S. Department Of Defense·Kansas

56% match

Switchgear Transformer Replacement

Closes 11/16/2026Opened 10/28/2026

U.S. Department Of Defense·Pennsylvania

56% match

TRANSFORMER, PSRL

Closes 11/2/2026Opened 9/30/2026

Iowa State University·Iowa

55% match

CP1269515-Utilities-Pearson Substation-4.16kV Switchgear and Cable Infrastructure Upgrade

Closes 11/3/2026Opened 10/6/2026

Massachusetts Peabody Municipal Light Plant·Massachusetts

55% match

THREE PHASE 23KV PADMOUNT TRANSFORMERS

Closes 11/5/2026Opened 10/20/2026

U.S. Department Of Defense·United States of America

55% match

TRANSFORMER

Closes 11/6/2026Opened 9/25/2026

Chelan County PUD·Washington

55% match

Mobile Substation Purchase - Mobile 6

Closes 12/17/2026Opened 10/22/2026

LA Water & Power·California

55% match

146852 DS-80 Bank 4 High Side Transformer

Closes 11/6/2026Opened 10/21/2026

University of Maryland - Baltimore·Maryland

55% match

Electrical Substation Expansion and Improvements at Towson University

Closes 12/8/2026Opened 10/28/2026

County of Sonoma·California

55% match

BID 500 kVA outdoor pad-mounted transformer

Closes 11/6/2026Opened 10/22/2026

City of Gallup·New Mexico

55% match

Turnkey-Engineering, Procurement and Construction (EPC) for New Carbon Coal Electrical Substation

Closes 11/6/2026Opened 7/24/2026

Southeastern Pennsylvania Transportation Authority·Pennsylvania

55% match

Pole Mount Transformer

Closes 11/4/2026Opened 10/21/2026

Grand River Dam Authority - GRDA·Oklahoma

54% match

Tonnece 69 kV Terminal Addition Project - Substation & Transmission

Closes 11/20/2026Opened 10/26/2026

NYS Rochester-Genesee Reg. Transportation Authority·New York

54% match

Fueling Station Electrical Distribution Upgrades

Closes 11/20/2026Opened 10/26/2026