This contract is for lead abatement work at 3594 Elm Rd, Stow, Ohio 44224. The work includes removing existing windows, making repairs, and installing new white vinyl windows. The contractor must follow all applicable local building codes and regulations, including OSHA and HUD requirements. The contract has a mandatory pre-bid meeting and requires the contractor to have a current registration, bond, and insurance on file with the appropriate jurisdiction's building department. The contractor must also provide a copy of each permit and signed-off inspection sheet to complete the paperwork for the project. Some key points to note are:
* The contractor must attend the mandatory pre-bid meeting to submit a bid.
* The contractor must have a current registration, bond, and insurance on file with the appropriate jurisdiction's building department.
* The contractor must follow all applicable local building codes and regulations, including OSHA and HUD requirements.
* The contractor must provide a copy of each permit and signed-off inspection sheet to complete the paperwork for the project.
* The contract must be completed within 30 days of signing.
* The contractor must list the county of Summit as an additional insured on their insurance policy.
* The contractor must pay federal Davis Bacon wage rates.
* The contractor must provide all necessary labor, materials, services, and equipment to complete the work.
* The contractor must verify all counts on windows during the pre-bid meeting and bid accordingly.
* No change orders will be allowed for missed windows after the pre-bid meeting.
* The contractor must provide warranties for all work and materials.
* The contractor must respond to all phone calls and emails within 24 hours.
* The contractor must complete the job within 30 days of signing the contract.
* The contractor must not start work until the client has been relocated.
Some of the specific work items include:
* Removing all existing windows and making repairs as needed
* Installing new white vinyl windows with a minimum 5/8" insulated air space and screens
* Wrapping and caulking all exposed exterior wood casing with aluminum coil stock
* Insulating around windows prior to installing stops
* Reinstalling any existing window trim
* Installing smoke detectors in each sleeping area and on each floor
* Installing a battery-operated CO detector by the fuel source
* Replacing the garage man door with a steel pre-primed pre-hung door with weather stripping and a dead bolt.