Bid Banana
PricingBid helpAPILog inStart free trial
Log inStart free trial

Learn more

  • Federal contracts (SAM.gov)The Ultimate Guide to SAM.gov Registration
  • Compliance checkHow to Ensure RFP Compliance
  • How to answer an RFPChoosing and Responding to Government Bids
More manufacturing bids →Must-win bid? Bring in The Bid Lab →
Bid Banana
SearchPricingBid helpBrowse bidsAPISupportFAQPrivacy PolicyTerms of UseAI Use Policy

This website and its content is copyright of The Bid Lab © 2026. The Bid Lab is a trademark of Bid Lab, LLC. All rights reserved.

  1. Bid Banana
  2. ›Closed bids
  3. ›Federal
  4. ›Commercial Diesel Generator Set, 600kW Standby 60Hz

U.S. Department Of Defense·New York

Commercial Diesel Generator Set, 600kW Standby 60Hz

Closes 5/13/2026$500k – $2MRequest for Proposal
Bid source

This opportunity has closed.

Bid Banana tracks 1.6M+ bids and awards across all 50 states. Save a search and we'll email your new matches, daily or weekly — so the next one reaches you with time to bid.

Get alerted next time

Description

The US Army is seeking a commercial diesel generator set with a 600kW standby power rating at 60Hz. The generator set should have a duty rating for standby power, emission certification, and EPA Tier 2 compliance. The set should also have a UL 2200 listing, a voltage of 277/480, and a 3-phase, 4-wire configuration. The alternator should be 60Hz, wye, and 480 volts. The generator set should also have an alternator heater, a steel sound-attenuated level 2 enclosure, and an exhaust system. The enclosure should be green, and the cooling air outlet should be horizontal. The distribution panel should be prewired with AC features, and the fuel tank should be 2400 gallons, UL142 compliant, and have a high fuel fill alarm. The control mounting should be left-facing, and the power command 2.3 controller should have an LCD control display. The stop switch should be emergency and externally mounted, and the signals should have auxiliary 8 inputs/8 outputs. The circuit breaker or entrance box should be right-only, and the terminal box should be low voltage, left-none. The engine air cleaner should be normal duty, and the external battery charger should be 12 amps, regulated. The engine cooling should be radiator, 50C ambient, and the shutdown should be low coolant level. The coolant heater should be 208/240/480 volts AC, below 40F ambient temperature. The genset warranty should be 2 years base, and the literature should be in English. Some key features of the generator set include: • 600kW standby power rating at 60Hz • Duty rating for standby power • Emission certification and EPA Tier 2 compliance • UL 2200 listing • Voltage of 277/480, 3-phase, 4-wire configuration • Alternator heater and steel sound-attenuated level 2 enclosure • Exhaust system and high fuel fill alarm • Pre-wired distribution panel with AC features • 2400-gallon fuel tank, UL142 compliant • Left-facing control mounting and power command 2.3 controller • Emergency stop switch and auxiliary signals • Normal duty engine air cleaner and external battery charger • Radiator engine cooling and low coolant level shutdown • Coolant heater and 2-year base genset warranty

Attached files

The solicitation documents live at the source — open the bid source above to download them.

Contact

Carrie Lawton

[email protected]

(772) 1065

Key dates

Opened
5/6/2026
Closes
5/13/2026

Last updated

Details

Type
Request for Proposal
Industry
Manufacturing
NAICS
335312
Solicitation №
W911S226U3180

Budget estimate

$500,000 – $2,000,000

The budget for this opportunity is difficult to estimate without more information about the contract terms and the number of generator sets being purchased. However, based on the specifications and the complexity of the generator set, it is likely that the budget will be in the range of $500,000 to $2 million. This estimate is influenced by the fact that the generator set has a high power rating, is designed for standby power, and has a number of advanced features such as emission certification, EPA Tier 2 compliance, and a steel sound-attenuated enclosure. Additionally, the fact that the US Army is the purchasing agency suggests that the budget may be higher due to the strict requirements and specifications of the military.

AI estimate from the solicitation

Similar opportunities

Matched by Bid Banana AI™

Bid Banana · 1.6M+ bids and awards 🍌

You found this one too late. Don't find the next one too late.

Bid Banana searches open government bids across all 50 states, updated daily. Save a search once and we email you your new matches, daily or weekly, while there is still time to win them.

1.6M+
bids & awards
All 50
states
4,000+
agencies
Start your 7-day free trial

Plans from $49.99/month. Cancel anytime, no setup fees.

Built by The Bid Lab, answering RFPs since 2017.

U.S. Department Of Defense·Maryland

Top match · 74%

Diesel Engine, Starter Motor, Magnetic Contactors, Powerpack & Alternators Supporting 800kW, 60 Hz DPGDS - Non-Commercial NSN's

Closes 11/9/2026Opened 10/8/2026

South Carolina Rural Water Association (SCEMD Grant)·South Carolina

72% match

Mobile Diesel Generator - 100kW

Closes 11/23/2026Opened 10/19/2026

Jefferson Parish Sheriff's Office·Louisiana

72% match

New Diesel Generator

Closes 11/25/2026Opened 10/28/2026

U.S. Department Of Defense·Maryland

70% match

Diesel Engine, Starter Motor, Magnetic Contactors, Powerpack & Alternators Supporting 800kW, 60 Hz DPGDS - Commercial NSN's

Closes 11/9/2026Opened 10/15/2026

Kanawha County Commission·West Virginia

70% match

Bid Specs for Cedar Grove Tower Generator

Closes 11/6/2026Opened 10/6/2026

Jefferson Parish Sheriff's Office·Louisiana

70% match

25-NOV-2501 New Diesel Generator

Closes 11/25/2026Opened 10/28/2026

U.S. Department Of Defense·Washington

69% match

750kW Emergency Diesel Generator (EDG) Rental (PSNS&IMF)

Closes 11/5/2026Opened 10/23/2026

City of Mexico Beach·Florida

69% match

Purchase & Installation of s 48-kW Deisel Generator

Closes 11/16/2026Opened 10/19/2026

Town of Tyrone·Georgia

68% match

2026 Generator Replacement Sewer Pump Station #3

Closes 11/4/2026Opened 10/5/2026

Wyoming Department of Transportation·Wyoming

68% match

GENERATOR REPLACEMENT

Closes 11/10/2026Opened 10/9/2026

U.S. Department Of Defense·United States of America

68% match

Replace DSN-HDD Generator for 78th Signal Battalion, Camp Zama, Japan.

Closes 11/9/2026Opened 10/18/2026

City of Plant City·Florida

68% match

Plant City Utilities Communication Tower Generator Replacement (FEMA)

Closes 12/3/2026Opened 10/22/2026

State of Delaware OMB·Delaware

68% match

Prickett Building Generator Replacement

Closes 11/24/2026Opened 10/8/2026

City of Memphis·Tennessee

68% match

Generator Service for General Services

Closes 11/4/2026Opened 10/16/2026

Illinois DOT - Transportation·Illinois

67% match

REBID District 3 Ladd and Sycamore Maintenance Yard Generator and Installation

Closes 11/5/2026Opened 10/15/2026

Maryland State Highway Administration·Maryland

67% match

70EMGEN30SB_EMERGENCY/STANDBY GENERATOR MAINTENANCE

Closes 11/4/2026Opened 10/21/2026

Kanawha County Commission·West Virginia

67% match

Bid Specs for Sumerco Tower Generator

Closes 11/6/2026Opened 10/6/2026

U.S. Department Of Health And Human Services·Oklahoma

67% match

Emergency Generator Preventive Maintenance, Repair, Emergency Callout & Rental Services

Closes 11/6/2026Opened 10/28/2026

City of Davenport·Iowa

67% match

Generator Services

Closes 11/12/2026Opened 10/26/2026

U.S. Department Of Defense·Oklahoma

67% match

Generator, Direct Cu

Closes 10/14/2027Opened 10/14/2026

U.S. Department Of Justice·Texas

67% match

Install Generator- FCI Bastrop

Closes 12/2/2026Opened 10/23/2026

Central Ohio Transit Authority (COTA)·Ohio

67% match

Generator PM & On Call Services for COTA Facilities

Closes 11/10/2026Opened 10/20/2026

Massachusetts Department of Correction·Massachusetts

66% match

2019-DOC-1000-New and Used Generators

Closes 12/11/2027Opened 5/10/2019

City of Lynn Haven·Florida

66% match

Generator Maintenance

Closes 11/16/2026Opened 10/26/2026

Kenai Peninsula Borough·Alaska

66% match

ITB27-026 South Peninsula Hospital Generator

Closes 11/3/2026Opened 10/7/2026